Addonics Technologies AD5EHPMEU3 Computer Drive User Manual


 
www.addonics.com
Phone: 408-573-8580
Fax: 408-573-8588
Email: http://www.addonics.com/sales/query/
CONTACT US
The RAID and Disk Information screen (shown when the program was
launched) will now show the Port Multiplier with an Array. The drives are now
listed as M0-M4, indicating they are members of the array. If spares are
present (individual drives added later, and the EZ switch is in the OFF
position), they would be listed as S0, S1, etc. On the right pane, the RAID
Level, status, capacity and members that are online are listed. Status will show
“Normal” (all members on line), “Degraded” (a fault-tolerant array with a drive
failure needing service), “Rebuilding” (a fault-tolerant array in the process of
reconstructing lost data onto a spare) or “Broken” (an array that has lost all
data).
In the event of a drive failure, the Jmicron RAID Manager will present a dialog
box such as the one shown below, even if it is currently minimized to the system
tray: