ADTRAN 239 T1 HDSL4 Network Card User Manual


 
239 T1 HDSL4 Repeater (H4R) Installation and Maintenance Practice H4R Capacity Guidelines
61223445L1-5D 7
6. H4R CAPACITY GUIDELINES
The ADTRAN 239 H4R is designed for installation in a prewired apparatus case, and the capacity guidelines for deployment are defined in Table 3 and
Table 4. These housing capacity numbers are based upon testing results.
Table 4. 239 H4R Capacity Guidelines for ADTRAN Housings
Part
Number
Description CLEI Code Slots Stub
H4R Capacity
Recommended Slot
Assignments
Material
Above
Ground
Below
Ground
Above
Ground
Below
Ground
1150027L1 239/439 Housing DDMOABA1MA 4 Air 4 4 All All Stainless/Polymer
1150027L2 239/439 Housing DDMOBBA1MA 4 Gel 4 4 All All Stainless/Polymer
1150057L1 Universal Housing DDMODA01RA 4 Air 4 4 All All Stainless Steel
1150057L1 Universal Housing DDMODA01RA 4 Gel 4 4 All All Stainless Steel
1150058L1 Universal Housing DDMOEE01RA 8 Air 8 8 All All Stainless Steel
1150058L2 Universal Housing DDMOFE01RA 8 Gel 8 8 All All Stainless Steel