8. MAINTENANCE
The HDSL4 239 T1 HDSL4 Repeater (H4R) requires no routine maintenance for normal operation. In case of
equipment malfunction, perform an in-band loopback from the Central Office. If a malfunction is confirmed,
replace the unit.
The ADTRAN 239 H4R has looping capability through the channel allowing digital loopback in fault isolation.
The loopback is activated remotely. The type of loopbacks the H4R supports will be dependent upon the loopback
capabilities of the transceiver units utilized on the circuit. Refer to the Installation and Maintenance Practice of the
specific H4TU-C or H4TU-R for a list of loopback codes.
Performance monitoring, diagnostics, and loopbacks are also available from the craft interface at the
H4TU-C or H4TU-R.
CAUTION
When testing indicates a faulty H4R, refer to the housing Installation and Mainte-
nance Practice for the entry and pressurization control, the replace the faulty unit.
ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning
the defective unit to ADTRAN. Refer to “Appendix A, Warranty” for further information.
9. SPECIFICATIONS
Specifications for the HDSL4 239 T1 HDSL4 Repeater (H4R) are detailed in Table 7.