ADTRAN Hub Switch User Manual


 
10Base-T Hub Installation and Maintenance Practice
4 61181012L1-5C
Compliance
CAUTION
Electrostatic discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist strap
to prevent damage to electronic components. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved antistatic
mat that is electrically grounded.
Figure 2 shows the compliance codes for the 10Base-T Hub. The 10Base-T Hub is NRTL-listed
to the applicable standards. It meets or exceeds all the applicable requirements of NEBS,
Telcordia GR-63-CORE, and GR-1089-CORE.
The 10Base-T Hub is intended for deployment in Central Office (CO) type facilities, EEEs,
EECs, and locations where the NEC applies.
CAUTION
Per GR-1089-CORE, the 10Base-T Hub is designed and intended
for installation as part of a Common Bonding Network (CBN). The
10Base-T Hub is not designed nor intended for installation as part
of an Isolated Bonding Network (IBN).
CAUTION
Per GR-1089-CORE Section 9, the 10Base-T Hub is designed and
intended only for installation in a DC-C (common) bonding and
grounding system. The 10Base-T Hub is not intended or designed
for installation in a DC-I (isolated) bonding and grounding system.
NOTE
The 10Base-T Hub (P/N 1181012L1) does not require the use of an
external AC Surge Protection Device. However, for highly exposed
AC mains environments, an external AC Surge Protection Device is
recommended.
Table 2. Compliance Codes
Code Input Output
Power Code (PC) A
Telecommunication Code (TC) X
Installation Code (IC) F C