ADTRAN Hub Switch User Manual


 
10Base-T Hub Installation and Maintenance Practice
8 61181012L1-5C
8. Put the 10Base-T Hub on the wall-mounted bracket.
9. Connect the RJ-45 cables. Refer to the “Connections” on page 10 in this practice.
Rack-Mount Installation
There are two procedures for mounting the 10Base-T Hub to a rack.
“Chassis-Mount Instructions” on page 8
“Bay Framework-Mount Instructions” on page 9
Tools Required
The following tools are require to mount the 10Base-T Hub to a rack:
Small flat-tip screwdriver
#1 Phillips-head screwdriver
Line cutters
Chassis-Mount Instructions
To mount the 10Base-T Hub to a chassis, complete the following steps:
NOTE
The 10Base-T Hub ships pre-assembled to the external mounting
bracket, and unassembled from the internal mounting bracket.
The 10Base-T Hub must be disassembled before performing the
following instructions. See
Figure 3 and Figure 4 for details on dis-
assembling and assembling the 10Base-T Hub.
1. Remove the hub from the external mounting bracket by removing the flathead screw near
the power connector that secures the hub to the bracket. Slide the hub away from the tab
and lift off the bracket (see
Figure 4).
2. The external mounting bracket is designed to replace either of the side flanges that mount
the chassis to the bay. Carefully remove either of the side flanges attached to the chassis
and replace them with the mounting bracket provided with the10Base-T Hub. Tighten the
chassis to the bay. Ensure two phillips-head screws are attached to the center two holes
closest to the edge opposite the flange on the bracket.
3. Attach the 10Base-T Hub to the mounting bracket through the keyholes on the bottom of
the 10Base-T Hub. The front panel of the 10Base-T Hub must be facing the side flange.
4. Use the flush mount phillips-head screw to secure the 10Base-T Hub to the bracket
through the small lip on the side of the bracket. The orientation is correct if the lip is flush
against the 10Base-T Hub on the side containing the power connection terminal block.
5. Put the 10Base-T Hub on the rack-mounted bracket.
6. Connect the RJ-45 cables. For more information, refer to the “Connections” on page 10 in
this practice.