ADTRAN QDFR Unit Network Card User Manual


 
Menu Descriptions
61181307L7-5E 21
Channel T1 Threshold Alarm History Screen
An individual Channel T1 Threshold Alarm History screen (Figure 25) provides the errored
seconds, severely errored seconds, loss of signal seconds, code violation line, and code
violation path.
Figure 25. Channel T1 Threshold Alarm History Screen
Event History Screen
The Event History screen (Figure 26) displays various events that have taken place, including
changes to service states and alarms.
Figure 26. Event History Screen
Shelf: 1 Slot: 11 Total Access System mm/dd/yy hh:mm
Unacknowledged Alarms:
CH 1 Circuit ID:
T1 Alarm History
LOCATION THRESH ALARM FIRST LAST CURRENT COUNT
--------------------------------------------------------------------------------
QDFC ESL 15MIN OK 000
(DSX-1) SESL 15MIN OK 000
LOSSL 15MIN OK 000
CVL 15MIN OK 000
ESP 15MIN OK 000
SESP 15MIN OK 000
UASP 15MIN OK 000
CVP 15MIN OK 000
--------------------------------------------------------------------------------
1. Clear ALL CH 1 Data 4. View Next Channel
2. Toggle Network/Customer Data 5. View Fiber Alarms
3. 24 HOUR Data R. Clear ALL Alarm Data
Selection:
Shelf: 1 Slot: 11 Total Access System mm/dd/yy hh:mm
Unacknowledged Alarms:
Num Description of Event Date Time Source Port
-----------------------------------------------------------------------------
1. QDFR Event Log Reset 08/04/04 08:39:54 QDFR SYS
Page Number: 1/ 1 Number of Events: 1
-----------------------------------------------------------------------------
'P' - Previous Page 'H' - Home 'R' - Reset Events
'N' - Next Page 'E' - End
Selection: