Alcatel-Lucent 6850-48X Switch User Manual


 
12 Booting OmniSwitch 6850 Series Switches June 2007
Booting a Standalone Switch
The OmniSwitch 6850 Series switch does not use an on/off
switch. The power cord is the switch’s only connect/discon-
nect device. The power connector socket is located on the
switch’s rear panel. For more information, refer to the
OmniSwitch 6850 Series Hardware Users Guide.
To boot the switch, plug the power cord (provided) into the
power connector socket at the switch’s rear panel. Next, plug
the power cord into an easily-accessible power source, such as
a grounded AC outlet or an Uninterruptible Power Supply
(UPS).
The switch immediately begins the boot process. Allow a few
moments for the switch to boot completely, then verify the
status of all LEDs on the switch’s front panel. A successful
boot for a standalone switch displays the following LED
states:
Booting OmniSwitch 6850
Series Switches
LED States for a Standalone Switch
OK Solid green
PRI Solid green
PWR Solid green
BPS Solid amber, if BPS attached is failed;
off, if no operational BPS is attached;
solid green if an operational BPS is
attached and operating normally.
XFP1 Off (applies to all OmniSwitch 6850
Series switches except for the
OmniSwitch 6850-24X,
OmniSwitch 6850-P24X,
OmniSwitch 6850-48X,
OmniSwitch 6850-P48X, and
OmniSwitch 6850-U24X).
XFP2 Off (applies to all OmniSwitch 6850
Series switches except for the
OmniSwitch 6850-24X,
OmniSwitch 6850-P24X,
OmniSwitch 6850-48X,
OmniSwitch 6850-P48X, and
OmniSwitch 6850-U24X).
Slot Indicator 1–8 (non-blinking), depending on the
slot number value in the boot.slot.cfg
file. See the OmniSwitch 6850 Series
Hardware Users Guide for detailed
information. The default value is 1.
LED States for a Standalone Switch