What’s New in Version 3.0.0.41
New Software Features
None
Resolved Issues
In some cases where more than one switch has the same STP Bridge Priority value in a
network, the switch with the higher MAC address would be elected as the STP root
bridge. This issue has been resolved.
Operational Notes
100 Mbps SFP: Switch over back to fiber fails after fiber link restored. It happens when
an LCP155A4HSR 100M SFP is used when backup Copper link is 1G.
Recommended User Work Around: Works fine when fiber and Copper speeds are
similar and there are no issues with different SFP model.
Port Mirroring: Port mirroring closes the port and opens it again.
Recommended User Work Around: Not required.
TAB functionality: Use of the Tab key does not complete the command Interface range
VLAN all and the command Switchport general allowed VLAN.
Recommended User Work Around: Type in the full command.
SNMP - EWS > SNMP > Notify > Filters: Cannot add or modify filter with name
containing special characters.
Recommended User Work Around: Do not use special characters.
Time - EWS > System > System Time: The current day becomes undefined after
changing Time Zone Offset.
Recommended User Work Around: The current day will be displayed correctly when
the switch is reset.
Web Response Time: Upon full table configuration it takes longer time to open the page
IPv6 Neighbors and the page Statistics->RMON Alarm.
Flow Control: Flow control does not work on the Gigabit ports.
Recommended User Work Around: No work around.
Encryption: It is impossible to add MD5/SHA keys via EWS.
Recommended User Work Around: Use CLI commands.
Syslog: Fail to add one syslog server with a description of maximum length including
some space.
Recommended User Work Around: Do not use spaces and avoid using the maximum
allows length of the description.
LLDP: When in mixed stack of PoE and Non PoE units, you can configure the PoE-PSE
optional TLVs for non-PoE ports and these non-PoE ports will be advertised.
Recommended User Work Around: Do not configure the PoE-PSE optional TLVs for
non-PoE ports, so that this information will not be advertised.
TACACS: When using the single connection option, the first login or “enable” attempts
will fail, but the retry works.
Recommended User Work Around: Use the multiple connection option (default
setting).