Allied Telesis AT-FS705LE Switch User Manual


 
AT-FS705LE Installation Guide
17
Check to be sure that the power outlet has
power by connecting another device to it.
Try replacing the power adapter with
another power adapter.
2. Check the Link/Act LED for each port. The
LED should be lit steady or flashing. If a
Link/Act LED is OFF, check the following:
Check to be sure that the node connected
to the port on the switch is powered ON. If
the node is OFF, power the unit ON.
Check to be sure that the distance
between the switch and the connected
network device is no greater than 100
meters (328 feet).
Check to be sure that you are using
Category 5 cable.
Check to be sure that the cable has not
been cut or damaged.
3. If the Lnk/Act LED for a port is on but there
is a communication problem to the end node
connected to the port, such as the loss of data,
check the following:
Check to be sure that the distance
between the switch and the connected
network device is no greater than 100
meters (328 feet).