Allied Telesis AT-SBX31XZ4 Switch User Manual


 
SwitchBlade x3112 Installation Guide
195
Figure 147. SHOW FANMODULE Command
5. To view the states of the control and line cards in the chassis, use the
SHOW CARD command.
An example of the status information is shown in Figure 148. A card is
operating normally when its state is UP-UP-ONLINE. If there is a
problem with a card, refer to “Ethernet Line Cards” on page 201 or “AT-
SBx31CFC Central Fabric Controller Card” on page 209 for
troubleshooting suggestions.
Figure 148. SHOW CARD Command
6. To check the status of PoE on the ports of the AT-SBx31GP24 Line
Card, use the SHOW POE INTERFACE=ALL command.
Ports that are delivering power to powered devices have the value
Powered in the Power Status column of the display. If there is a
problem, refer to “Power Over Ethernet” on page 205 for
troubleshooting suggestions.
For information about the command line interface, refer to the Software
Reference for SwitchBlade x3100 Series Switches on the Allied
Telesis web site.
SHOW FANMODULE
--- Fan Module ---
Fan Module..................... FM4
Module Number.................. AT-SBxFAN12
Serial Number.................. 102
State.......................... UP-UP-Online
Actual
Fan Speed
Fan 1.................. 2685 rpm
Fan 2.................. 2724 rpm
Fan 4.................. 2702 rpm
Fan 4.................. 2690 rpm
Cold Temperature Shutdown... Off
SHOW CARD
--- Card Information ---
Prov
Slot Card Type State Faults
---- --------- ------------------- ------
0 GE24RJ UP-UP-Online -
1 GE24RJ UP-UP-Online -
2 GE24RJ UP-UP-Online -
3 GE24RJ UP-UP-Online -