13
the holes in the fan are secured to the mount.
3. Use the long screws provided to secure the fan to the mount.
Do not overtighten.
4. Run the power (and control switch if using a TriCool™ fan)
through the cable guide that runs along the side of the mount.
5. Clip the assembly onto the back of an empty HDD cage.
6. Connect the fan to the power supply.
4.4 Washable Air Filters
Front Air Filters – There is a filter located behind the faceplate of each HDD cage faceplate. Two front air
filters come with the case by default.
To clean the filters:
1. Remove the cage thumbscrews fastening the HDD cage to the 5.25” drive bays and set them
aside.
2. Slide the HDD cage forward about 1 or 2 inches. You will see the air filter behind the faceplate.
Note: There should be no need to disconnect the power or data connections from the HDD or
the fan in order to remove the filters for cleaning if you have left about 2 inches of slack in the
cables.
3. Lift the tab upwards to remove the filter.
Side Air Filter – There is a filter located in the side fan bracket. It is located on the inside of the side
panel, so you must open the side panel to access it. Remove the filter by sliding it out of the bracket.
From time to time it will be necessary to wash the installed air filters. Not washing the air filter will result
in high system temperatures and possible stability problems. We recommend checking the air filter at
least once a month initially. The frequency will change depending on environmental conditions and
system usage. Users who run their systems 24/7 will have to check their filters more often than those
who don’t run their systems every day.