Asus ASMB-LE Computer Hardware User Manual


 
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)
ASUS Server Management Board (ASMB-LE)ASUS Server Management Board (ASMB-LE)
ASUS Server Management Board (ASMB-LE)
2-72-7
2-72-7
2-7
A:\>asmc -bmc_ip 169.254.137.105
Detect MotherBoard -> (PSCH-LR)
Detect KCS Interface
New BMC IP : 169.254.137.105
A:\>
4. Run the ASMC utility from the support CD following the instructions in
the previous section.
5. Type
asmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxx
asmc -bmc_ip xxx.xxx.xxx.xxxasmc -bmc_ip xxx.xxx.xxx.xxx
asmc -bmc_ip xxx.xxx.xxx.xxx, then press <Enter> to
assign any IP address to the remote server LAN port. The screen
displays the request and response buffer. Write the remote server IP
address in a piece of paper for reference.
A:\>asmc -bmc_mac
Detect MotherBoard -> (PSCH-LR)
Detect KCS Interface
Bus Dev Fun Vendor-Device MAC
======== ====== ======= ====== ============== ===================
PSCH-LR 01 01 00 8086 - 1075 00-11-2F-0F-A2-21
New BMC MAC: 00 11 2F 0F A2 21
A:\>
6. Type
asmc -bmc_mac asmc -bmc_mac
asmc -bmc_mac asmc -bmc_mac
asmc -bmc_mac on the prompt, then press <Enter>. The
screen displays the physical address (MAC) of the remote server.
Write the MAC address in a piece of paper for reference.
When finished, the utility returns to the DOS prompt.
Make sure that the assigned IP address for both remote and local/central
servers are in the same subnet. You can use the network settings utility
in your OS to check.
7. Type
asmc -bmc_info asmc -bmc_info
asmc -bmc_info asmc -bmc_info
asmc -bmc_info on the prompt, then press <Enter> to
display the IP and MAC addresses of the BMC and PET.
8. Restart the remote server, enter the BIOS setup, then boot from the
hard disk drive.
9. Adjust the local/central server network settings, if necessary.
A:\>asmc -bmc_mac
Detect MotherBoard -> (PSCH-LR)
Detect KCS Interface
BMC IP : 169.254.137.105
BMC MAC: 00 11 2F 0F A2 21
PET IP : 169.254.137.106
PET MAC: 00 E0 18 9B BB 44