Asus P9DI Computer Hardware User Manual


 
5-28
Chapter 5: RAID configuration
3. When prompted, use the arrow keys to select
Yes
from the
Consistency Check?
dialog box then press <Enter>.
A progress bar appears on screen showing the progress of the consistency check.
4. While checking the disk consistency, press <Esc> to display the following options.
Stop - Stops the consistency check. The utility stores the percentage of disk
checked. If you restart the consistency check, it will continue from the
percentage it stopped and continues the checking with the remaining
percentage that is not yet checked.
Continue - Continues the consistency check.
Abort - Aborts the consistency check. When you restart checking, it starts from
zero percent.
5. When checking is complete, press any key to continue.
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
Yes
No
Consistency Check?
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011
BIOS Version A.11.02090932R
The Data On The Drives Is Inconsistency. Repair Done!
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
85% Completed