Asus PI4 Server User Manual


 
5-18 Chapter 5: RAID conguration
5.2.5 Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the
Objects>Adapter
menu.
The
Check Consistency
command is available only for virtual drives included
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the
Check Consistency
command
1. From the
Management Menu
, select
Check Consistency
, and then press
<Enter>.
2. The screen displays the available RAID set(s) and prompts you to select
the virtual drive to check. Press <Space> to select the virtual drive from the
Virtual Drive
sub-menu, and then press <F10>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.07211059R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Select VD
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Virtual Drives
Virtual Drive 0
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.07211059R
SPACE-(De)Select, F10-Check Consistency