Barco R9002139 Projector User Manual


 
Random Access Adjustment Mode
6-5
5975039 BARCOVISION 508 071298
Note : No horizontal phase adjustment is available on the internal #
pattern.
For external sources :
If the raster shift is correctly adjusted, the H Phase text box is
projected in the middle of the raster. At that moment, the "><" icon
indicates the middle of the raster.
Adjust the H Phase control until the middle of the projected image is
equal with the middle of >< icon.
Note :
- If the genlocked pattern was selected, the external source will be
displayed.
A bar scale and a number indicator (between 0 and 100) on the
screen give a visual indication of the horizontal phase adjustment.
Select with or
then <ENTER>
<EXIT> to return.
GEOMETRY
H PHASE
RASTER SHIFT
LEFT-RIGHT (E-W)
TOP-BOTTOM (N-S)
H SIZE
V LINEARITY
V SIZE
BLANKING
ENTER continues to geometry menu .
Push the control disc to
the right to correct
Push the control disc to
the left to correct
Horizontal Phase Adjustment
Push the control disc up or down to highlight H PHASE on Geometry
menu and then press ENTER.
H PHASE
><
70
H PHASE
><
70
H PHASE
70
><
Raster Shift Adjustment
The green raster must be centered both horizontally and vertically on
the center of the CRT surface. To center the green raster, look into
the green lens and use the control disc to move the raster.
CAUTION
It is necessary to look into the lenses to perform these adjustments.
To avoid eye discomfort while looking into the lenses, reduce the
contrast and gradually increase the brightness level until the raster
becomes visible on the face of the CRT.
ENTER will select green raster shift adjustment
EXIT returns to random access adjustment mode menu.
Select with or
then <ENTER>
<EXIT> to return.
GEOMETRY
H PHASE
RASTER SHIFT
LEFT-RIGHT (E-W)
TOP-BOTTOM (N-S)
H SIZE
V LINEARITY
V SIZE
BLANKING