Bay Technical Associates DS4-RPC Switch User Manual


 
DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________
53
DS73TP
The DS73TP peripheral communications
CONFIGURATION
module supports remote access to TCP/IP
Ethernet networks by using the DS71 or
DS71-MD2 module and the DS Series Data
Switch. Remote users can dial into the
system and connect to the network host from
anywhere, at anytime. In-band network
management is achieved using the DS73TP
module via the DS71 or DS71-MD2 module
and a PPP Dial-Up session
IMPORTANT:
For network access, you must configure the
Module and Dial-up IP addresses, Subnet Mask, and Gateway
Address. The module must be reset for network changes to take
effect.
From the main menu, select C,
“Configuration,” followed by <cr>, or exit
from the main menu and send the ASCII
character string $BTCONFIG<cr>.
The following selection menu appears:
Configuration
Module 1 ................................................1
Module 2 ................................................2
Module 3 ................................................3
Select Port .............................................S
Exit ........................................................X
Enter Request :
From the selection menu, select the DS73TP
module number, followed by <cr>. For
example, If the DS73TP is installed as
module 2, select #2, “Module 2.” The
following header appears: