B&B Electronics Five Port Expandable Smart Switch Switch User Manual


 
232XS53800 Manual
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5109
14
You could then send SWB$ to select port B of Expansion switch
unit address “C”. Similar strings could be used for turning on the
other ports. To turn off the ports the string might look like this:
TOFF$ = CHR$(27) + CHR$(2) + CHR$(4)
When you are done with a port you can either select a new one
directly or turn off the selected port and then turn on the next one.
For information on preventing command codes from being received
by slave devices, refer to the Enhanced Mode section.
Table 9 - 232XS5 Expander Mode Commands
* X represents the programmable character set by dipswitch SW2
** NU = Not Used
***Port C is used as the expansion port for unit addresses B thru D.
Command Characters
Function 1st 2nd 3rd 4th Comments
Select Port A ESC X* “A” “A” Address A
Select Port B ESC X* “A” “B” Address A
Select Port C ESC X* “A” “C”*** Address A
Select Port D ESC X* “A” “D” Address A
Select Port E ESC X* “A” “E” Address A
Select Port A ESC X* “B” “A” Address B
Select Port B ESC X* “B” “B” Address B
Select Port D ESC X* “B” “D” Address B
Select Port E ESC X* “B” “E” Address B
Select Port A ESC X* “C” “A” Address C
Select Port B ESC X* “C” “B” Address C
Select Port D ESC X* “C” “D” Address C
Select Port E ESC X* “C” “E” Address C
Select Port A ESC X* “D” “A” Address D
Select Port B ESC X* “D” “B” Address D
Select Port D ESC X* “D” “D” Address D
Select Port E ESC X* “D” “E” Address D
Deselect Port ESC X* EOT NU** Switching Command
Set Timer Value ESC X* “T” “0”-”9” Enhanced Mode
Set Timer Mode ESC X* “M” “0”,”1” Enhanced Mode