B&B Electronics Multi-Interface Ethernet Serial Servers Server User Manual


 
Server Properties Configuration
Manual Documentation Number: ESP901-902_4105m Chapter 5 39
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Figure 33. The Restart Dialogue Box
The following dialogue box will appear:
Figure 34. The Restarting Dialogue Box
After eight seconds a dialogue box will ask whether you want to search
for all reachable servers again.
Figure 35. The Server Search Dialogue Box
While the Serial Server is searching for all reachable servers the
following dialogue box appears:
Figure 36. The Search VLINX ESP Dialogue Box
Server Properties Configuration
40 Chapter 5 Manual Documentation Number: ESP901-902_4105m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
After that port has been updated you may want to re-enter Server
Properties to verify the changes have taken effect, or to view/change
the configuration of other ports. Each port must be configured
separately.
Saving Configuration Data in Console Mode or Telnet
Saving (updating) server properties is done from the Configuration
screen. Access the Configuration screen by tabbing through the list of
screens on the left side of the window and highlighting
Configuration.
There are four options shown on the right side of the
Configuration
screen: Save, Default, Running and Reset. Use Tab, Backspace, or
arrow keys to move the cursor to the option position, then press Enter.
Console Mode and Telnet Configuration Screens
Save stores the configuration data to the
Serial Server flash
memory and resets it.
Default restores the configuration data to factory default settings.
Running restores the configuration data to the last values stored in
the flash memory.
Reset re-boots the
Serial Server, making it available for a client
connection.