Maintenance30
LED Status & Description
Power Temp Lamp
Power events
Power switch on
--
Power-up cooling. The projector needs 90 seconds to cool down
as it was abnormally shutdown without the normal cooling
dowm sequence.
--
Stand-by mode.
--
Lamp LED is blinking during powering up.
--
Power-down cooling for 90 seconds after power has been turned
off.
--
Normal operation
Lamp events
--
It is warning you that lamp usage has exceeded 2000 hours.
Replace the projection lamp with a new one immediately.
--
The lamp is not properly attached or the lamp is damaged.
Please contact your dealer for assistance.
Thermal events
-
The projector will shutdown automatically. If you re-turn on
the power, the projector will shutdown again. Please contact
your dealer for assistance.
The projector will shutdown automatically. If you re-turn on
the power, the projector will shutdown again. Please contact
your dealer for assistance.
The projector will shutdown automatically. If you try to restart
the projector, it will shutdown again. Please contact your dealer
for assistance.
O O O
O
O
G
O
G
R
R
R
R
R
R
G
R
R
G