No. Description Value
range
Factory
setting
14 “FiFo” = “Requ” + “Free”:
0 = MCS 223 does not turn off another microphone unit
1 = MCS 223 turns off another microphone unit
0 or 1 1
15 “FiFo” = “Requ” + “Free”:
0 = MCS 223 is not turned off by another microphone unit
1 = MCS 223 is turned off by another microphone unit
0 or 1 1
16 Warning signal in the “Free” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec. 45
17 After the speech time has elapsed in the “Free” mode
0 = Timer indicates the exceeded speech time (counts up)
1 = MCS 221 is turned off
0 or 1 0
18 Warning signal in the “Request” mode before the speech time has elapsed;
0 = no warning signal
0 ... 59 sec. 45
19 After the speech time has elapsed in the “Request” mode:
0 = Timer indicates the exceeded speech time (counts up)
1 = Timer stops (activated MCS 221 is turned off and the registered MCS 221
must be activated by the chairman with the “Requ” button)
2 = Timer starts again (activated MCS 221 is turned off and registered
MCS 221 is turned on)
0 ... 2 2
20 Speech time is displayed in minutes (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 99 min. 2
21 Speech time is displayed in seconds (applies to “Free” and “Request” mode
(no. 20 and 21 are added)
0 ... 59 sec. 30