4.4.4 Configuration – WAN Configuration
The screens below contain settings for the WAN interface toward Internet.
VPI: Consult the telephone company to get the Virtual Path Identifier (VPI) number. The
default value is 8.
VCI: Consult the telephone company to get the Virtual Channel Identifier (VCI) number.
The default value is 35.
Static IP Address: Enter the information provided by your ISP.
Subnet Mask: Enter the information provided by your ISP.
Default Gateway: Enter the gateway address provided by your ISP.
ATM
Service Category: Select UBR or CBR.
Bandwidth: Enter the bandwidth.
ENCAPSULATION
There are eleven ways PPPoE VC-Mux, PPPoE LLC, PPPoE None, PPPoA VC-Mux,
PPPoA LLC, 1483 Bridged IP VC-Mux, 1483 Bridged IP LLC, 1483 Routed IP VC-Mux,
1483 Routed IP LLC, Classical IP over ATM, Native ATM for the device to have a
public IP address and then to access Internet. You have to check with your ISP about
which way is adopted.