5-4 Gap Sensor Manual-Calibration
Manual-calibration of media detection can be used when the printer cannot detect a media
gap (or black mark) even after auto-calibration has been executed.
Users can calibrate sensor parameters in detail by using the utility program provided by
the manufacturer.
The utility can be obtained from the enclosed CD or downloaded from the Internet via the
BIXOLON website www.bixolon.com
Please make sure the printer is connected and execute the utility program.
Press the Calibration Setting Manager button after setting the interface type.
1) Select proper values for "No. of detect" and "Detect margin" and press the Execute
Manual Calibration button to make the printer begin media sensor calibration.
2) Typically-used setting values are pre-saved in the Setting buttons (1~8).
3) If the printer malfunctions while executing calibration, please turn off the printer and turn
it on again.
4) The sensor parameters can be set back to factory default settings by pressing the
Cancel Calibration button.