Black Box 3600 MODEM Modem User Manual


 
Hardware Options
Modem 3600 E-31
Factory Option Set # 4
(Synchronous 4-wire Leased Line)
(AT&F4)
MODEM OPTIONS TEST OPTIONS
DCE rate - 33600 Bilateral digital loop enabled *
V.34 modulation * DTE local test disabled
V.34 rate threshold low * DTE remote test disabled
V.34 asymmetric rate disabled * Remote commanded test enabled
Normal originate Test timeout off
Fast train disabled
Auto retrain enabled DIAL LINE OPTIONS
SQ auto rate disabled Tone dial
Transmit clock internal Auto dial #1
Leased line * Wait for dial tone
4-wire * Wait delay 2 seconds
Transmit level - 0 dBm * Pause delay 2 seconds
Dial backup manual * Call timeout 60 seconds *
Lookback timer - 15 min * Answer on 1 ring
Jack type RJ11 Autocallback disabled
Line current disconnect long
Long space disconnect enabled DTE OPTIONS
V.22 guard tone disabled Sync data *
AT command set disabled *
PROTOCOL OPTIONS Ignores DTR *
LAPM protocol disabled * DSR normal *
MNP protocol disabled * DCD normal
Direct buffer mode * CTS follows RTS *
DTE flow control disabled * RTS/CTS delay 0 ms *
DCE flow control disabled * DTE fallback disabled
XON/XOFF pass through disabled Options retained at disconnect
Inactivity timer off
Break control 0 *
V.42 fast detect disabled *
SPEAKER OPTIONS
Volu me low
On until carrier detect
*
Indicates variation from factory option set #1