Chapter 3: Installation
3. Installation
1. Connect the SHDSL line to the DSL RJ-48 connector on the LR0201A-KIT’s rear panel.
Figure 3-1. RJ-48 connector, Pins 4 and 5.
2. Connect the Ethernet interface to the RJ-45 port with the included CAT5 cable.
3. Connect the included power cord to the AC outlet.
CAUTION: Verify that the AC–DC adapter conforms to your country’s AC power requirement and then insert the power plug.
NOTE: The Interconnecting cables should be rated for external use and for the application’s voltage, current, anticipated
temperature, flammability, and mechanical serviceability.
4. Turn on the power switch. Set one G.SHDSL Two-Wire Ethernet Network Extender as CO (master) site from console port, and
the other as remote (slave) site.
5. Set the desired data rate for the SHDSL connection from the console port.
NOTE: Both G.SHDSL Two-Wire Ethernet Network Extenders must have the same data rate settings.
6. Both G.SHDSL Two-Wire Ethernet Network Extenders will automatically connect with each other.
NOTE: Turn on the power switch, and LR0201A-KIT will then execute self-test routines. There will be two or more
handshaking cycles when adaptive rate is selected. The system will automatically adapt to the maximum rate according
to the loop distances. The maximum rate is 5.696 Mbps for a 1-pair SHDSL line.
Pin 4 and Pin 5 for SHDSL line