CD Network Tower Status LEDs
No. of Fault Corrective
Blinks Indication Action
0 Solid red Return to dealer; unit failed power-on self-test.
1 Blinking yellow No network found; check network cabling.
2 Blinking yellow Boot server not set; configure CD Network Tower.
3 Blinking yellow Boot filename not set, configure CD Network Tower.
4 Blinking yellow Boot server not found; configure CD Network Tower.
5 Blinking yellow Boot filename bad or not found. Verify that SYS:\LOGIN
directory on boot server has .IMG file shown in More
Info—Details in the Tools menu.
6 Blinking yellow SCSI terminator power. Use “Fileserver Information”
dialog to display detailed SCSI errors (check SCSI
cables). Select the attached CD Network Tower, then
select More Info—Details from the Tools menu.
7 Blinking yellow SCSI bus hung. Use “Fileserver Information” dialog to
display detailed SCSI errors (check SCSI cables).
Select the attached CD Network Tower, then select
More Info—Details from the Tools menu.
9, 10 Blinking red Call for technical support.
Solid yellow Unattached CD Network Tower. Use DiscView to
display error. Select the unattached CD Network Tower,
then select More Info from the Tools menu.