Black Box LB1351A Switch User Manual


 
Black Box®LB1350A/LB1351A
19
Appendix-A : Managing the Black Box® LB1351A
1.Preface
This appendix provides you with the necessary information for managing the
Black Box® LB1351A Traffic Aggregator (monitor and control).
In order to start managing your Black Box® LB1351A
you need to setup the
management module parameters (section 2). In addition you will need to set proper
network connection (section 3) and to install the attached MIB file (section 4).
After the management parameters are set, you can manage the Black Box®
LB1351A
in either of two ways: using SNMP (through a standard management
station – section 5) and using a Terminal (section 6).
2.Setting Up Management Parameters
Terminal connection
Have available a PC equipped with any terminal emulation program (any ASCII
terminal).
Use the supplied control cable to connect the converter to the PC: connect the
miniDIN end of the cable to the RS232 port on the converter and the other end to
an available DB9 (male) connector on the PC.
Configure the terminal emulation program as follows:
baud rate: 9600
parity: none
start bits: 1
stop bits: 1
flow control: none
Start the terminal emulation then reset the device.
Startup screen
After a few seconds you will get the start up screen (figure 2-1).
Note: the parameters appearing in the figures are just examples. Set them to
the values you need.
At this point, you should immediately press any key in order to get to the
management configuration procedure. You will get a notification that will enable you
to modify the current settings by typing ‘m’ (or ‘M’).
At this stage you will be prompted with a series of questions regarding the
management parameters configuration. The configuration procedure screen is
shown here in figure 2-2. Default value for each parameter appears in braces. If you
do not wish to change a certain parameter, simply hit ‘Return’.The different
parameters are explained in detail in figure 2-2. Default value for each parameter
appears in braces.If you do not need to change a certain parameter, simply hit “
Return “.The different parameters are explained in details in figure 2-2.