Black Box LB1351A Switch User Manual


 
Black Box®LB1350A/LB1351A
35
Advanced port configuration
Advanced port configuration table is located under
flLta31mPorts/flLta31mPortAdvanced in the device’s MIB sub-tree. The table is
shown in figure 7-7.
figure 7-7 – advanced port configuration
SNMP traps
The management application also allows you to receive traps sent by the device (figure
7-8). Traps are sent by the Black Box® LB1351A after every configuration change. In
addition traps will be sent to alert of the following events:
System up (cold start)
Temperature (when exceeds 65
0
C for more than 1 minute)
TP link down
FO link down
TP link up (after at least 10 seconds down)
FO link up (after at least 10 seconds down)
Device reset (management initiated)
* traps for configuration changes will specify the initiator of the change (either local user
or remote manager) where applicable.