Black Box LES114BA Server User Manual


 
Level 4 Logs all data transferred to the port and all changes in hardware flow control
status and all User connection events
Click Apply
Note A cache of the most recent 8K of logged data per serial port is maintained locally (in addition to
the Logs which are transmitted for remote/USB flash storage). To view the local cache of logged
serial port data select Manage: Port Logs
7.6.3 Network TCP and UDP port logging
The console server supports optional logging of access to and communications with network attached
Hosts.
For each Host, when you set up the Permitted Services which are authorized to be used, you also
must set up the level of logging that is to be maintained for each service
Specify the logging level that is to be maintained for that particular TDC/UDP port/service, on
that particular Host:
Level 0 Turns off logging for the selected TDC/UDP port to the selected Host
Level 1 Logs all connection events to the port
Level 2 Logs all data transferred to and from the port
Click Add then click Apply
7.6.4 Auto-Response event logging
Check Log Events on Alerts & Logging: Auto-Response to enable logging all Auto-Response
activities
7.6.5 Power device logging
The console server also logs access and communications with network attached hosts and maintain a
history of the UPS and PDU power status.
To activate and set the desired levels of logging for each serial (Section 7.4) and/or network port (Section
7.5) and/or power and environment UPS (refer Chapter 8)
_____________________________________________________________________
724-746-5500 | blackbox.com Page 148