Chapter 3: Installation and Initial Setup
Figure 3-26. Modbus ID Routing Screen.
c. The first box in line is the starting ID of a range you want to route. Valid value range is from 1 to 247.
d. The second box in line is the last ID of that range. Valid value range is from 1 to 247.
e. The third box in line is a port or IP address that has slave devices attached.
f. The fourth box in line is an IP address of the slave device if IP address is chosen in the third box.
g. Save settings by clicking the “Save” button.
14. See the Modbus Priority screen.
a. To access this screen, click the “Next” button or click the “Modbus Priority” link on the left side of the screen.
b. This screen allows you to configure the Modbus Hardened Serial Server to move high priority messages to the front of the
serial message buffer.