Black Box MWU2000-X21 Modem User Manual


 
81
2.048Mb
p
s Wireless Modem
TECHNICAL: 0118 931 2233
Message: WARNING: Net I.D. too high (relevant only regarding
synchronization)
Description: The Net I.D. for a link that should be synchronized is higher that the requested
number of links to synchronize.
Correction: Adjust the Net I.D.
Message: WARNING: Difference in parameter(s) between two
units
Description: Different setting of parameters in the two units forming the links. This
message will be followed by more details, as follows:
Normal/Test Mode Setting: one of the units is in Test mode and the
other one is set to Normal mode.
HOP Standard Setting: different HOP standards setting are used in the
two units.
HOP Sequence setting: different hopping sequences are selected in the
two units.
Test Sequence channels: different sequences used in test mode
Clock Rate: different clock rates selected in the two units.
Delay Setting: different link delay settings in the two units.
Master/Slave setting: both units are defined as Master.
Echo Canceler parameters: in a fractional E1/T1 application,
different echo canceler parameters (disabling method) are selected in the two
units.
E1/T1 Channel Selection: in a fractional E1/T1 application, different
channels are selected in the two units.
Echo Canceler Channels: in a fractional E1/T1 application, a
difference in the channels in which echo cancellation is used in the two units.
E1/T1 Parameters setting: different parameters used in the two units
in a E1/T1 application.
Correction: Configure the parameters properly.
Note: HOP Standard setting can only be configured by an authorized Black Box technician.