Briggs & Stratton 8 Power Supply User Manual


 
11
Emergency
Stop
Safety Cage
Pressure Filter
Return Filter
Drum Circuit
Arm Circuit
Blower Circuit
Jack Circuit
FUNCTION
DESCRIPTION GREEN LED RED LED OFF
Green LED indicates that no
Emergency Stop buttons have
been pressed.
Green LED indicates that all
Access Doors are closed.
Green LED indicates that
the Pressure Filter is in good
condition.
Green LED indicates that
the Return Filter is in good
condition.
Green LED indicates that the
drum valve has been activated
and the potentiometer (position
sensor) is reading the Drum
Position.
Green LED indicates that
the arm valve (server) has been
activated and the
speed sensor is reading the
motor rotation.
Green LED indicates that
the Blower Circuit has been
activated.
This function is not used.
Red LED indicates that one of
the Emergency Stop buttons
has been pressed.
Red LED indicates that one
of the Access Doors is open or
the Tilt Panel is not tilted open.
Red LED indicates that the
Pressure Filter is full and in
need of cleaning / replacing.
The Red LED will stay lit until
maintenance is completed. The
trailer will continue to operate at
a reduced performance level.
Red LED indicates that the
Return Filter is full and in
need of cleaning / replacing.
The Red LED will stay lit until
maintenance is completed. The
trailer will continue to operate at
a reduced performance level.
Red LED will display if the drum
is not moving.
If the drum circuit has been
activated and the drum is
moving, but the red LED is
constantly lit, the potentiometer
isn’t reading a change in the
Drum Position. This would
indicate that either the
potentiometer is bad or the
valve isn’t operating.
The red LED may flash while
the drum is moving. This is nor-
mal.
Red LED will display if the
arm is not moving.
If the Arm Circuit has been
activated and the arm is moving,
but the red LED is constantly lit,
the speed sensor isn’t reading a
change in the arm position. This
would indicate that either the
speed sensor is bad or the valve
isn’t operating.
The red LED may flash while
the arm is moving. This is nor-
mal.
Both LEDs would be OFF when
the Drum Circuit isn’t activated
at all.
Both LEDs would be OFF when
the Arm Circuit isn’t activated
at all.
LED would be OFF when the
Blower Circuit isn’t activated
at all.