6. Clean the primary corona wire inside the drum unit by gently sliding
the tab to the right and left several times.
Fig. 6-23 Cleaning the Primary Corona Wire
7. Return the tab to the home position (▲ mark position) before
reinstalling the drum unit.
!
Caution
Be sure to position the tab at the home position, or printed pages may
have vertical stripes.
8. Install the drum unit into the machine.
See the section “REPLACING THE DRUM UNIT” in this chapter.
9. Close the top cover.
10. Plug in the power cord and turn on the
power
switch.
Home Position (
▲
)