Cabletron Systems 2E43-51R Switch User Manual


 
General Configuration Screen
2E43-51/2E43-51R User’s Guide 5-21
4. Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in Figure 5-10 displays.
Figure 5-10 Configuration Warning Screen
5. Use the arrow keys to highlight the YES command, then press
ENTER. The changes are saved and the device reboots.
5.7.2 Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
2E43-51 is located on a separate subnet, the subnet mask for the 2E43-51
may need to be changed from its default.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Dotted Decimal Notation
(DDN) format.
For example: 255.255.0.0
WARNING!
19601-84
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS MODULE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
NO