Cabletron Systems 9E106-06 Network Card User Manual


 
A-3
EPIM-F3
EPIM-F3
The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal
Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equipped with ST
Connectors. Figure A-3 shows the EPIM-F3. Specifications for the EPIM-F3 are
listed in Table A-3.
The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on
single mode fiber-optic cable as specified by ANSI SMF-PMD.
Figure A-3. EPIM-F3
Table A-2. Transmitter Power Parameters
Parameter Typical Value
Worst
Case
Worst Case
Budget
Typical
Budget
50/125 µm fiber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125 µm fiber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140 µm fiber -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB
Error Rate Better than 10
-10
The transmitter power levels and receive sensitivity levels listed are Peak Power
Levels after optical overshoot. A Peak Power Meter must be used to correctly
compare the values given above to those measured on any particular port. If
Power Levels are being measured with an Average Power Meter, then 3 dBm must
be added to the measurement to correctly compare those measured values to the
values listed (i.e., -30.5 dBm peak = -33.5 dBm average).
NOTE