INSTALLATION
Page 3-2
2. Attach the strain relief bracket to the bottom of the TRXI as shown
in Figure 3-1.
Figure 3-1. Attaching the Strain Relief
3.3 INSTALLING THE TRXI
The TRXI can be rack mounted, wall mounted, or placed on any
horizontal surface. Select one of the following subsections and perform
the steps that are applicable for your installation. If you decide not to
install the TRXI in a 19-inch rack, the following requirements must be
met when selecting a location.
Note: Be sure that the location selected is within reach of the network
cabling.
An unrestricted free surface area at least 21 inches wide, 18
inches deep and 6 inches high is needed.
A single phase 85 to 264 Vac, 15A, grounded power receptacle
must be located within 7 feet of the site.
If a shelving unit is to be used, it must be able to support 30
pounds of static weight.
The temperature for the selected location must be maintained
between 5° and 50°C, and less than 10°C per hour temperature
change.
TRXI-24A TOKEN RING HUB WITH LANVIEW®