Casio DT-X5 Computer Hardware User Manual


 
20
Table 2.2 Operating hours by model
Model
WLAN
IEEE802.11b
Scan
engine
Battery
Operating
hour
Operating mode
Alkaline batteries Approx. 200
HA-A20BAT Approx. 90
DT-X5M10E No Laser
DT-5025LBAT Approx. 180
Scanning 2 times per 10
seconds.
HA-A20BAT Approx. 90
DT-5025LBAT Approx. 180
Scanning 2 times per 10
seconds
HA-A20BAT Approx. 15
DT-5025LBAT Approx. 30
Wait : RF : scan = 6.5:2:1.5
HA-A20BAT Approx. 20
DT-X5M10R Yes Laser
DT-5025LBAT Approx. 40
Wait: RF: scan: calculation =
20:1:1:1
Alkaline batteries Approx. 42
HA-A20BAT Approx. 40
DT-X5M30E,
DT-X5M30U
No C-MOS
DT-5025LBAT Approx. 80
Scanning 2 times per 10
seconds.
HA-A20BAT Approx. 40
DT-5025LBAT Approx. 80
Scanning 2 times per 10
seconds.
HA-A20BAT Approx. 15
DT-5025LBAT Approx. 30
Wait : RF : scan = 6.5:2:1.5
HA-A20BAT Approx. 20
DT-X5M30R Yes C-MOS
DT-5025LBAT Approx. 40
Wait: RF: scan: calculation =
20:1:1:1
Notes:
The durations of time in “Operating hour” for DT-X5M10R have been measured in the WLAN
configuration with Cisco Aironet 1100 Access-Point. These time durations may become different if other
Access-Point is employed.
The durations of time in “Operating hour” are measured under the conditions that new battery pack (or new
alkaline batteries) is used, the surrounding temperature is at 25 ºC and the dedicated test program is used.
In the low temperature, the operating hour powered by battery tends to be shorter.
Table 2.3 Readable 1D bar code symbologies
Symbology Output format/Append function
C-MOS
imager
Laser
scanner
EAN8/JAN8 2-digit/5-digit addon Yes Yes
EAN13/JAN13 2-digit/5-digit addon Yes Yes
UPCA NS output
2-digit/5-digit addon
Yes Yes
UPCE NS output
UPCA conversion
2-digit/5-digit addon
Yes Yes
Code39 Start/stop output
ASCII conversion
Yes Yes
Codabar (NW7) Start/stop bit output Yes Yes
Interleaved 2of5 (ITF) Yes Yes
Code93 Yes Yes
Code sets A/B Yes Yes Code128
Code set C Yes Yes
MSI (Plessey) Yes Yes
IATA Yes Yes
Code11 Yes No
RSS-14 Standard/Truncated Yes Yes
RSS Limited Yes Yes
RSS Expanded Standard Yes Yes
ISBT Yes No
Industrial2of5 (IDF) No Yes