E-65
Useful features
Advanced programmings and registrations
Programming detail settings
To program the detail settings of the register, please follow the operations shown
below.
Step Operation
1 Turn the Mode switch to PGM position and select [System
Setting] then press F key.
[System Setting] is the last column on the programming top
menu and is not shown on the rst screen. Keep pressing
> key until it appears on the screen.
>▪▪▪▪▪>F
2 Enter 3 and press o key to set the register in the
programming mode.
3o
3 Referring the following tables, enter two-digit set code you
wish to program followed by two 2s. “22” is the identica-
tion code for programming detail settings.
BB22
[set code]
For example, if you wish to program tax
system:
0422
4 Referring the tables below, enter program code of up to 10
digits and press F key.
BB▪▪▪▪▪BBF
[Program code (up to 10 digits)]
5 Press o key to complete the program.
o
Set code 02 (Machine number)
Description Selection Program code Default value
Machine number Machine
number
BBBB
D4 D3 D2 D1
ºººº
D4 D3 D2 D1
Example: To set the register’s specic unit number 1234.
Press 3o0222o1234Fo
Set code 03 (Whether to reset consecutive number after Reset (Z) report or not)
Description Selection Program code Default value
Reset consecutive number after daily reset report is issued. Yes = 0
No = 1
B
D8
º
D8
Must be “0000000” (seven zeros)
B to B
D7 to D1
º to º
D7 to D1
Example: Not resetting the consecutive number after Z report printing.
Press 3o0322o10000000Fo