4. Operating Instructions 9 1/13/2011 5:38 PM
Operation
DMX Operation
This operating mode will allow for control with an external DMX controller. You must set the
starting address for this mode.
If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer”
section in the “Appendix” of this manual.
Please see the instructions below for details on this mode.
1. Plug the fixture into power.
2. Plug a DMX controller into the fixture in a daisy chain configuration.
3. Press <MODE> until Addr appears on the LED screen.
4. Press <ENTER>.
5. Using <UP>&<DOWN>, select the DMX starting address.
6. Press <ENTER>.
DMX Channel Values
CHANNEL
VALUE
FUNCTION
1
000 010
011 045
046 080
081 115
116 150
151 185
186 220
221
255
Pod 1
Blackout
Red
Green
Blue
Yellow
Magenta
Cyan
White
2
000 010
011 045
046 080
081 115
116 150
151 185
186 220
221
255
Pod 2 (run speed when CH.8 is between 011~239)
Blackout
Red
Green
Blue
Yellow
Magenta
Cyan
White
3~6
000 010
011 045
046 080
081 115
116 150
151 185
186 220
221
255
Pod 3~6
Blackout
Red
Green
Blue
Yellow
Magenta
Cyan
White
7
000009
010
255
Strobe
No function
Strobe (slow~fast)
8
000010
011047
048095
096119
120144
145167
168191
192215
216239
240
255
Mode
Individual pod control with strobing (channels 1~7)
Automatic 1
Automatic 2
Automatic 3
Automatic 4
Automatic 5
Automatic 6
Automatic 7
Automatic 8
Sound-active