Cisco Systems 3650 Switch User Manual


 
A-2
Catalyst 3650 Switch Hardware Installation Guide
OL-29734-01
Appendix A Technical Specifications
Switch Specifications
Operating temperature ranges and
altitude (DC power supply installed)
Normal operating temperature
1
and altitudes:
–5ºC to +45ºC, up to 6000 feet (1800m)
–5ºC to +40ºC, up to 10,000 feet (3000m)
–5ºC to +35ºC, up to 13,000 feet (4000m)
–5ºC to +30ºC, up to 16,400 feet (5000m)
Short-term exceptional conditions
1
2
:
–5ºC to +55ºC, up to 6000 feet (1800m)
–5ºC to +50ºC, up to 10,000 feet (3000m)
–5ºC to +45ºC, up to 13,000 feet (4000m)
–5ºC to +40ºC, up to 16,400 feet (5000m)
–5ºC to +45ºC, at sea level with single fan failure
Relative humidity 5 to 96% (non-condensing)
Storage temperature –40 to 158° F (–40 to 70° C)
Storage altitude Up to 16,400 ft (5000 m)
Physical Specifications
Dimensions (H x W x D)
Catalyst 3650 24-port non PoE switches
Catalyst 3650 24-port PoE+ switches
Catalyst 3650 48-port non PoE switches
Catalyst 3650 48-port PoE+ switches
Catalyst 3650 48-port Full PoE switches
Dimensions include the chassis assembly as it is shipped:
three fans, two Stackwise adapter blanks, one power supply
blank, and the default power supply shipped with the unit.
1.73 x 17.5 x 17.625 in. (4.4 x 44.5 x 44.8 cm)
1.73 x 17.5 x 17.625 in. (4.4 x 44.5 x 44.8 cm)
1.73 x 17.5 x 17.625 in. (4.4 x 44.5 x 44.8 cm)
1.73 x 17.5 x 17.625 in. (4.4 x 44.5 x 44.8 cm)
1.73 x 17.5 x 19.125 in. (4.4 x 44.5 x 48.6 cm)
Weight
Catalyst 3650 24-port non PoE switches
Catalyst 3650 24-port PoE switches
Catalyst 3650 48-port non PoE switches
Catalyst 3650 48-port PoE switches
Catalyst 3650 48-port Full PoE switches
StackWise stacking adapter
StackWise adapter blank
Weight includes the chassis assembly as it is shipped: three
fans, two Stackwise adapter blanks, one power supply
blank, and the default power supply shipped with the unit.
15.15 lbs (6.87 kg)
16.00 lbs (7.26 kg)
15.90 lbs (7.21 kg)
16.75 lbs (7.6 kg)
17.20 ibs (7.8 kg)
0.25 lbs (0.11 kg)
0.1 lbs (0.05 kg)
1. Minimum ambient temperature for cold start is 32°F (0°C).
2. Occurring not more than in one-year period: 96 consecutive hours, 360 hours in total, or 15 occurrences.
Table A-1 Environmental and Physical (continued)Specifications (continued)
Environmental Ranges