Configuring Frame Relay Service
Cisco MGX 8850 Installation and Configuration, Release 1.1.00, Part Number 78-6186-02
6-30
• lmi_sig specifies the LMI signaling. 1=Other, 2=None, 3=StrataLMI, 4=AnnexAUNI,
5=AnnexDUNI, 6=AnnexANNI, 7=AnnexDNNI LMI signalling, N=none,
S=StrataLMI, and au=AnnexAUNI.
• asyn enables asynchronous updates: (y)es or (n)o
• elmi enables Enhanced LMI: (N or n) disable (Y or y) enable
• T391 sets the T391 timer. The range is 5–30 seconds. It sets the interval in seconds for
NNI status polling. The default is 10.
• T392 sets the T392 timer. The range is 5–30 seconds. It sets the interval in seconds for
UNI status polling. The default is 15.
• N391 sets the N391 counter–the number of UNI/NNI polling cycles. The range is
1–255. The default is 6.
• N392 sets the N392 counter–the threshold for UNI/NNI errors. The range is 1–10. The
default is 3.
• N393 sets the N393 counter–the UNI/NNI threshold for monitored events. The range
is 1–10 and must be greater than the value of N392. The default is 4.
Step 6 Configure resources for the port as needed by executing cnfportrscprtn. To see the
partitioning, use dspportrscprtn. The description has a high and low-bandwidth version:
cnfportrscprtn <port_num> <controller> <percent BW> <low DLCI> <high DLCI>
<max LCN>
For FRSM-VHS cards:
• port_num is the port number in the range 1–2 for MGX-FRSM-2T3E3 and
MGX-FRSM-HS2 or 1–256 for MGX-FRSM-2CT3.
• controller is a number representing the controller: 1=PAR, 2=PNNI, and 3=Tag.
• percent BW is the percentage of the bandwidth in the range 0–100 and applies to both
egress and ingress.
• low DLCI is in the range 0–1023.
• high DLCI is in the range 0–1023.
• max LCN is the maximum number of logical connections available to the controller
on this port. The ranges are 1–4000 for MGX-FRSM-2CT3 and 1–2000 for
MGX-FRSM-2T3E3 and MGX-FRSM-HS2.
For AX-FRSM-8T1 or AX-FRSM-8E1:
• port_num is the logical port number in the range 1–192 for T1 or 1–248 for E1.
• controller-name is PAR, PNNI, or TAG.
• percent BW is the percentage of the bandwidth in the range 0–100 and applies to both
egress and ingress.
• low DLCI is in the range 0–1023.
• high DLCI is in the range 0–1023.
• max LCN is the maximum number of logical connections available to the controller
on this port. The range is 1–1000.