© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 12
Table 13. Power Specifications for the Cisco UC 560
Feature Description
AC input voltage 100 to 240V AC
AC input frequency 50 to 60 Hz
AC input current 3 to 1.5A (100 to 240V)
AC input surge current 30 to 60A (100 to 240V)
Power dissipation (AC) 67W
Table 14. Environmental Specifications for the Cisco UC 560
Feature Description
Operating temperature 32° to 104°F
Operating humidity
●
10% to 85% noncondensing, operating
●
5% to 95% noncondensing, nonoperating
Nonoperating temperature 4° to 149°F (-20° to 65°C)
Operation altitude
●
104°F (40°C) at sea level
●
87.8°F (31°C) at 6000 ft (1800 m)
●
77°F (25°C) at 10,000 ft (3000 m)
●
34.7°F (1.5°C) per 1000 ft
Dimension
(H x W x D)
3.5 x 17.25 x 13.78 in.
(8.89 x 43.82 x 35.00 cm)
Power supply dimensions (H x W x D) Internal power supply
Rack height 2 rack units (RU)
Weight (fully configured) 14.5 lb (6.58 kg)
Noise level (minimum and maximum) Normal operating temperature:
●
< 81°F (27°C): 37 dBA
●
< 93°F (34°C): 44 dBA
●
54 dBA (at maximum fan speed)
Table 15. Regulatory Compliance for the Cisco UC 560
Category Compliance
Safety
●
IEC 60950-1
●
AS/NZS 60950.1
●
CAN/CSA-C22.2 No. 60950-1
●
EN 60950-1
●
UL 60950-1
Immunity
●
EN 55024
●
EN 300-386
●
EN 61000-6-2
●
EN 50082-1
●
EN 55024 (CISPR 24)