Table 13. Power Specifications for the Cisco UC 560
Feature Description
AC input voltage 100 to 240V AC
AC input frequency 50 to 60 Hz
AC input current 3 to 1.5A (100 to 240V)
AC input surge current 30 to 60A (100 to 240V)
Power dissipation (AC) 67W
Table 14. Environmental Specifications for the Cisco UC 560
Feature Description
Operating temperature 32° to 104°F
Operating humidity
10% to 85% noncondensing, operating
5% to 95% noncondensing, nonoperating
Nonoperating temperature 4° to 149°F (-20° to 65°C)
Operation altitude
104°F (40°C) at sea level
87.8°F (31°C) at 6000 ft (1800 m)
77°F (25°C) at 10,000 ft (3000 m)
34.7°F (1.5°C) per 1000 ft
Dimension
(H x W x D)
3.5 x 17.25 x 13.78 in.
(8.89 x 43.82 x 35.00 cm)
Power supply dimensions (H x W x D) Internal power supply
Rack height 2 rack units (RU)
Weight (fully configured) 14.5 lb (6.58 kg)
Noise level (minimum and maximum) Normal operating temperature:
< 81°F (27°C): 37 dBA
< 93°F (34°C): 44 dBA
54 dBA (at maximum fan speed)
Table 15. Regulatory Compliance for the Cisco UC 560
Category Compliance
Safety
IEC 60950-1
AS/NZS 60950.1
CAN/CSA-C22.2 No. 60950-1
EN 60950-1
UL 60950-1
Immunity
EN 55024
EN 300-386
EN 61000-6-2
EN 50082-1
EN 55024 (CISPR 24)