Appliance Specifications
Dimensions Height: 42 mm (1.69 in)
Depth: 516 mm (20.33 in); includes power supply handles
Width: 429 mm (16.89 in)
Weight Maximum Weight (no carton): 10.21 kg (22.51 lb)
(Includes the weight of one Cisco Interface Module, one power supply,
and two hard disk drives.)
Electrical Input
Requirements
1
Range Line Voltage: 90 to 132 VAC, 180 to 264 VAC
Maximum Rated Input Current: 5 A - 2.5 A (100 - 240VAC)
Rated Input Frequency: 47 to 63 Hz
Maximum Real Input Power: 530W total (shared load when
redundant
BTU Rating 1808 BTU/hr Maximum
Power supply output
Rated steady-state power: 450 W (across input of 100 - 240 VAC)
Efficiency: Minimum of 85% at 100% electrical load
Acoustic noise
2
Idle: 43.9 dBA
Operating (70% load): 46.9 dBA
Environment
Air temperature:
Operating
3
: 0 to 40 °C (32 to 104 °F)
Non-operating: –30 to 60 °C (–22 to 140 °F)
Humidity:
Operating: 10% to 90% RH (non-condensing)
Nonoperating: 5% to 95% RH (non-condensing)
Altitude:
Operating: 3,050 m (10,000 ft)
Nonoperating: 4572 m (15,000 ft)
1. Electrical input specifications apply at 23 ºC (73.4 ºF).
2. Levels are A-weighted sound pressures measured in a 23 ºC (73.4 ºF) ambient environment. Measurements were made per
ISO 7779 (ECMA 74; ANSI S12.10) methods and are declared per ISO 9296 (ECMA 109).
3. All temperature ratings shown are for sea level to 1,000 meters (3,281 ft) with de-rating of maximum temperature for increase
in altitude. If operating location is above 1,000 meters (3,281 feet), deduct 3 ºC (5.4 ºF) from the maximum operating
temperature for each additional 1,000 meters (3,281 ft).
Table A-1 WAVE-594 and WAVE-694 Features and Specifications (continued)