43
Printer Operation
Menu Setting Table
Page Setup Menu - allows you to change settings related to the media or print quality.
System Setup Menu - allows you to change settings for the printer hardware and basic control systems.
After Print Menu - changes how the printer reacts after the label has been printed.
Interfaces - changes interface parameters such as baud rate.
Machine Information, Test Mode - allows you to check and/or print test pages and information about the printer.
Global Config menu - allows you to switch between 3 complete ‘config sets’ contained within the printer.
Menu Setting
Press the MENU key in print possible status to enter MENU Setup Mode. Use the keys on the operation panel
according to the LCD display to setup the printer. The contents that can be setup on the printer are shown
below. And the items that are actually displayed on the LCD are shown in [ ].
7 Datamax
®
Emulation
Top Menu Sub Menu Default Menu Remarks
Page Setup Print Speed* 7 IPS 2 to 10 IPS [For CL-S700/CL-S700R]
Printing speed setting.
7 IPS 2 to 8 IPS [For CL-S703]
Printing speed setting.
Print Darkness 12 00 to 30 Adjusting print darkness.
Darkness Adjust 00 -10 to 10 Fine adjustment of darkness commands.
[Darkness Adj]
Print Method TT TT (Thermal Transfer) Selection of Thermal Transfer (ribbon) or
DT (Direct Thermal) Direct Thermal.
Continuous Media 4.00 inch 0.25 to 32.00 inch Setting media length of continuous media.
Length 101.6 mm 6.4 to 812.8 mm Lower level = during mm mode.
[Cont Media Len]
Vertical Position 0.00 inch -1.00 to 1.00 inch Adjusting printing start position.
[Vertical Pos] 0.0 mm -25.4 to 25.4mm
Horizontal Shift 0.00 inch -1.00 to 1.00 inch Adjusting horizontal image position.
[Horizontal Shif] 0.0 mm -25.4 to 25.4mm
Vertical Image Shift 0.00 inch 0.00 to 32.00 inch Adjust the off set value in vertical when
[Vertical Image] 0.0 mm 0.0 to 812.8mm mapping data on a RAM.
Sensor Select Rear Adj Sensor Rear Adj Sensor Selecting front fixed/rear adj. sensor.
Front Fixed Sen
Media Sensor See Through See Through Selecting media sensor.
Reflect
None
Small Media Off On Setting for small media.
Adjustment Off
[Small Media Adj]
Small Media 1.00 inch 0.25 to 1.00 inch Setting media length for small media.
Length 25.4 mm 6.4 to 25.4mm
[Small Media Len]
Symbol Set PM 50 symbols Setting symbol set.
System Setup Sensor Monitor – – Displays level of sensor that is currently
selected.
Sensor Level 1.4 V 0.0 V to 3.0 V Selects threshold of the sensor.
Paper End Level 2.80 V 0.01 V to 3.00 V Sets the paper end level.
Error Reporting On Printing On Printing Setting for error report.
[Error Report] Immediate
Mode Settings
[Datamax
®
Emulation]
* 2 to 7 IPS for CL-S700/CL-S703 with optional peeler.