Citizen Systems CL-S700 Printer User Manual


 
39
Printer Operation
Top Menu Sub Menu Default Menu Remarks
Menu Key Action Enters Menu Enters Menu Sets the menu key action.
Repeat Last Set Enters Menu:
Repeat Last One Enters the menu setup mode.
Repeat Last Set:
Repeats the number of copies.
Repeat Last One:
Last one is issued only for the final page.
In the case of a count, afterwards, only
last one is issued.
Note: Hold down the MENU key for at least 4
seconds in order to enter the Menu Setup
Mode when setting the “Repeat Last Set” or
“Repeat Last One” menus.
Interfaces RS-232C Baud 9600 115200 Setting the baud rate of the serial interface.
57600 All settings related to the interface are
38400 enabled after the power is reconnected.
19200
9600
4800
2400
RS-232C Parity None None Setting the communication parity for the
Odd serial interface.
Even
RS-232C Length 8 bits 8 bits Setting the character length for the serial
7 bits interface.
RS-232C Stop bit 1 bit 1 bit Setting the stop bit for the serial interface.
[RS-232C Stopbit] 2 bits
RS-232C X-ON On Yes On Yes Selectively setting the X-ON flow control of
Off No the serial interface.
IEEE1284 On On Setting both direction of the Centro
Off Interface.
USB Device Class Printer Printer Selects the USB device class.
[USB Device Clas] VCOM
USB VCOM Protocol Auto Auto Selects the protocol (flow control) when
[VCOM Protocol] DTR operating USB VCOM.
X-ON
Machine Model Number CL-S*** Displays the model name.
Information
Boot Version *.* Displays the boot version.
[Machine Info]
ROM Version ******** Displays the ROM version.
ROM Date **/**/** Displays the date the ROM was prepared.
ROM CheckSum **** Displays the check sum of the ROM.
Head Check OK Displays the results of the head check.
NG
Print Counter ****.*** km Displays the print counter.
Service Counter ****.*** km Displays the service counter.
Sensor Monitor *.* V Displays the sensor level.
Option Interface None Displays the presence/absence of the
[Option I/F] LAN optional interface.
Test Mode Print Pattern Current Config Current Config Executes the test pattern.
Global Config
Sample
Head Check No Yes Executes head check.
No
Mode Settings
[Datamax Emulation]