Citizen Systems CLP-9301 Printer User Manual


 
Chapter 9 Specifications
56
9.2 Interfaces
1 Serial interface
Specifications
Transfer method: Start stop synchronous dual communication system
Signal level: RS-232C
Baud rate: 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps
Data bits: 7 or 8
Start bits: 1
Stop bits: 1 or 2
Parity: Even, odd, or none
Connector: D-SUB 25PIN 17LE-13250-27(D41)(DDK) or its equivalent
XON/XOFF protocol
XON code output requirements:
Communication is enabled after power is turned ON.
Residual capacity of the buffer is 1K bytes or more after sending XOFF code.
XOFF code is output due to error and printer returns to normal conditions.
XOFF code output requirements:
Printer is in error.
Printer is in paused state.
Receive buffer has less than 128 bytes available.