10. AC ADAPTOR
(1) Input voltage 100V ~ 240V AC (50/60 Hz)
(2) Input current 250 mA
(3) Rated output 9V ±5%
(4) Efficiency 65% or more (AC 100V/50 Hz full load)
70% or more (AC 240V/50 Hz full load)
(5) Ripple and noise voltage Less than 150 mVp-p (9 VDC)
(6) Insulation test More than 100M ohm
(DC 500V, 1 minute, between primary and secondary circuit and chassis)
(7) Leakage current 0.25 mA or less (AC 240V/50 Hz)
(8) Temperature rise 45K or less on case surface (100 VAC/50 Hz full load @25°C)
(9) Over voltage protection 120% - 150%
(10) Overload protection current 1.8 - 3.5A (AC 100-240, 25°C)
(11) No load power consumption 3W or less (AC 240V, 25°C)
(12) Safety standard UL, C-UL, PSE (10AD-JU)
VDE, GS, CE (10AD-E)
(13) Size 10AD-JU - 75 mm (L) × 50 mm (W) × 30 mm (H)
(14) Case material 94V-1
(15) Cable 1828.8 mm UL2468#22 × 2C
(16) Plug 3.5 × 1.3 × 9.5S
(17) Polarity Center ”+”
(18) Weight 104 g ±5g
11. EMI STANDARD
VCCI Class B
FCC Class B
EN55022