Cleveland Range PC-HACCP Personal Computer User Manual


 
Operating Instructions
3. CONVOTHERM PC-Control
page 4
10 July 2006 CONVOTHERM PC-Control
Delete a Step
1. Click the cardfile tab of the step to be deleted.
2. Click Delete Step.
3. The steps are automatically moved forward and renumbered.
3.2.3 Additional Functions
These functions can be used in programming:
HACCP-Criteria
The HACCP criteria can be entered in this window.
Notes
Comments about the Program can be entered here, e.g. recipe details, product
amounts or other tips.
Print
Click to print a Program.
To Program HACCP CRITERIA
1. Click on the HACCP button in the Programming window.
2. Click on CT (core temperature) and / or Oven.
3. If required, change the default values with the arrow keys, or type new values in the
entry fields.
4. Click on Time if desired (=Hold time for the core or cooking compartment temperature).
5. Click OK to save or Cancel to quit without saving.
To enter Notes
1. Click on the Notes button in the Programming window.
2. Enter text or insert from the clipboard.
3. Click OK or Cancel to quit without saving.
To Print
1. Click on the Print button in the Programming window.
2. Enter the printer information.
3. Click OK or Cancel to quit without saving.