Compaq SW3322 Switch User Manual


 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7
Compaq SW3322/SW3323/SW3324 Dual-Speed Switch User Guide
Writer: Fran Spragens Project: User Interface Comments:
File Name:3324_3.doc Last Saved On:3/16/99 3:05 PM
System Configuration Menu Descriptions continued
Selection Description
Power Up Diagnostics Allow you to enable (Yes) or disable (No) Diagnostics at power-up. Default is
Diagnostics enabled.
Screen Timeout (minutes)
The duration of time before a serial console or Telnet session terminates due to
user inactivity (0-65535 numeric range). A value of “0” means that the screen will
not terminate at any time.
Password Password allowing “read/write” access to the user interface, either via the serial
console or Telnet (1-10 character range).
Terminal Baud Rate The baud rate of the serial console interface (2400, 9600 or 19200).
Previous Menu Returns you to the previous menu.
SNMP Configuration Menu
The SNMP Configuration Menu allows you to modify SNMP-related configuration
parameters. Select a from the System Configuration Menu to view the SNMP
Configuration Menu. Figure 3-5 shows the SNMP Configuration Menu.
Figure 3-5 SNMP Configuration Menu
SNMP CONFIGURATION Access Control: READ/WRITE
a. SNMP Private Community Nameprivate
b. SNMP Public Community Namepublic
c. Trap Destination #1 000.000.000.000
d. Community Name #1
e. Trap Destination #2 000.000.000.000
f. Community Name #2
g. Trap Destination #3 000.000.000.000
h. Community Name #3
i. Trap Destination #4 000.000.000.000
j. Community Name #4
x. Previous Menu
Enter Selection: