60001024, Third Edition Installing the Omvia Media Server M110 2-3
About the M110
Environmental Requirements
To operate the system efficiently and safely, install and maintain the
Omvia Media Server M110 in a room with the appropriate temperature
and humidity.
The recommended location for the system is an office environment with
low dust content and an effective cooling and ventilation system. Install
the system within 5 feet of electrical outlets. A typical location is in the
room containing centralized telephone cabling, or near the PBX used by
the system.
Specifications
The environmental, dimension, and power specifications for the M110
are listed below:
Equipment Installation
Do not install the equipment in direct sunlight. Direct
sunlight can cause the system to overheat.
Table 2-1. M110 Specifications
Specification Properties
Storage Environment -40° C to 65° C or -40° F to 149° F
5% to 95% non-condensing humidity
Operating Environment 10° C to 35° C or 50° F to 95° F
8% to 80% humidity
Altitude Storage environment: 35,000 ft. maximum
Operating environment: 10,000 ft. maximum
Dimensions 17.6” W x 27.0” D x 1.67” H
Weight 35 lbs.
Power • Optional, hot plug, redundant 275 Watts power
supplies
• 110/220 Volts
• -48v DC power supply option