System Unit Tower
Dimensions
18.46 x 8.69 x 28 in/46.88 x 22.07 x 71.12 cm
Weight
70 lb/31.75 kg (without hard drives, no RPS)
Input Requirements
Range Line Voltage
90 to 264 VAC
Rated Input Voltage
90 to 264 VAC
Rated Input
Frequency
47 to 63 Hz
Rated Input Current
7.3A (110 V) to 3.6A (220 V)
Rated Input Power
800W
BTU Rating
2,732 BTU/HR
SCSI Connectors
Two Internal HD68 connectors and One External VHDCI
Connector supporting Ultra3
Power Supply Output
Power
Steady State Power
500 W
Maximum Peak
Power
550W
Temperature Range
Operating
41° to 95° F/5° to 35° C
Shipping
-40° to 185° F/-40° to 85° C
Relative Humidity
(non-condensing)
Operating
5% to 95%
Non-operating
5% to 95%
Maximum Wet Bulb
Temperature
101.7°F/38.7°C
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
L
WAd
(BELS)
5.9
L
pAm
(dBA)
41
Operating
(Random Seeks to Fixed Disks)
L
WAd
(BELS)
6.0
L
pAm
(dBA)
42
System Unit Rack
Dimensions
8.69 x 19.0 x 25.75 in/22.07 x 48.26 x 65.43 cm
Weight
65 lb/29.48 (without hard drives, no RPS)
Input Requirements
Range Line Voltage
90 to 264 VAC
Rated Input Voltage
90 to 264 VAC
Rated Input
Frequency
47 to 63 Hz
Rated Input Current
7.3A (110 V) to 3.6A (220 V)
Rated Input Power
800W
BTU Rating
2,732 BTU/HR
SCSI Connectors
Two Internal HD68 connectors and One External VHDCI
Connector supporting Ultra3
Power Supply Output
Power
Steady-State Power
500 W
Maximum Peak
Power
550W
Temperature Range
Operating
41° to 95° F/5° to 35° C
Shipping
-40° to 185° F/-40° to 85° C
Relative Humidity
(non-condensing)
Operating
5% to 95%
Non-operating
5% to 95%
QuickSpecs
Compaq ProLiant ML370 Generation 2
DA - 10901 Worldwide QuickSpecs — Version 40 — 3.11.2003